Starter Panels (DOL / Star-Delta / MCC) • ISO 9001 & Global Export

Motor Starter Panel (DOL / Star-Delta / Auto-Transformer)

Motor starter panel for 3-phase induction motors and submersible pump sets. DOL, Star-Delta, and Auto-Transformer variants with complete protection package.

HomeProductsStarter Panels (DOL / Star-Delta / MCC)Motor Starter Panel (DOL / Star-Delta / Auto-Transformer)
100% Factory PDI Tested
ISO 9001 / SASO / DEWA / UL
Global Export Packaging
11 Country B2B Direct Supply

Technical data sheet

Motor Starter Panel (DOL / Star-Delta / Auto-Transformer)

Motor starter panel for 3-phase induction motors and submersible pump sets. DOL (≤ 5 HP), Star-Delta (5–60 HP), and Auto-Transformer (≥ 60 HP) variants with complete protection package.

Characteristics

Motor RatingHP1 to 200
kW0.75 to 150
Starting method—DOL / Star-Delta / Auto-Transformer / Soft-Starter / Reactor
SupplyVolt380–415 (3Φ), 4-wire
FrequencyHz50
Short-circuit withstandkA10 / 25 / 50 (rating dependent)
Enclosure—Powder-coated MS, IP54 / IP55 / IP65
Protections—Overload, Short-circuit, Single-phasing, Earth fault, Under/Over voltage, Phase reversal
Control voltageV AC230 (control circuit derived from supply)
ApplicationsUsePumps, Blowers, Compressors, Conveyors, Machine drives, Industrial loads

Material of Construction — Power circuit

  • Incoming MCCB / MCB: Per IEC 60947-2, ICU 25 / 50 kA
  • Main contactor: AC-3 duty (Siemens / L&T / Schneider)
  • Star contactor (S-D): AC-3 duty, sized to 1/√3 of full-load current
  • Delta contactor (S-D): AC-3 duty, full-load current rated
  • Auto-transformer: Dry-type, copper wound, 50/65/80% taps (large frames)
  • Overload relay: Thermal / electronic with single-phasing protection
  • Star-delta timer: Adjustable 0–60 sec, electronic

Material of Construction — Control & enclosure

  • Control transformer: 230 V / 24 V (option), encapsulated
  • Indicators: LED indicators (R-Y-B, Run, Trip, Star, Delta)
  • Push buttons: Start / Stop / Reset (heavy-duty IP65 type)
  • Selector switch: Manual / Off / Auto rotary
  • Meters: Ammeter, voltmeter, hour-meter (digital)
  • Enclosure: 1.6 / 2.0 mm MS, powder-coated RAL 7035, IP54/55/65
  • Cable entry: Bottom gland plate with PG / brass glands

Salient Features

  • DOL (Direct On-Line) — for motors ≤ 5 HP
  • Star-Delta — for motors 5–60 HP, reduces inrush to ~33% of DOL
  • Auto-Transformer — for ≥ 60 HP, 50% / 65% / 80% taps available
  • Soft-starter option for jerk-free starting & extended motor life
  • Time-delay timer for star-to-delta transition (factory pre-set)
  • Single-phasing preventer & phase-reversal protection
  • Thermal overload with single-phasing protection
  • Earth-fault relay (optional)
  • Indicators, meters, & push buttons on front panel
  • Conforms to IEC 61439 / IS 8623

Applications

  • 3-phase pump motor starting (submersible & surface)
  • Blowers & compressors
  • Conveyor & machine drives
  • Mills, mixers & grinders
  • Industrial fan motors
  • Cooling tower fans
  • Workshop & machinery starting

Star-Delta only applicable for motors with all 6 stator terminals accessible (delta-rated at supply voltage).

For frequent-start service (>20/hour), prefer soft-starter or VFD over electromechanical starter.

Have a question? Drop us a line.

Share your duty point — head, flow, voltage, application — and our engineering team will match the right configuration.

Request quotationTalk to engineering

Quick Technical Answer & Duty Specification

ISO 9001:2015 Verified🇺🇸 60Hz / UL / NEMA — USA Import Ready

Motor Starter Panel (DOL / Star-Delta / Auto-Transformer) is an export-grade starter panels (dol / star-delta / mcc) manufactured in Ahmedabad, Gujarat, India by SUPERTECH WATER SOLUTION. Designed for B2B infrastructure, deep borewell lifting, municipal distribution, and agricultural irrigation, it features precision-balanced rotating assemblies, high-thrust bearings, and corrosion-resistant metallurgy.

Duty Flow / Q
Custom per duty point
Rated Head / TDH
Up to 500 meters
Motor / Power
0.5 HP – 100 HP
Supply Frequency
50 Hz & 60 Hz Dual Duty
100% Pre-Delivery Inspected (PDI)Direct Factory Pricing & OEM SupplySASO / SABER / CE / DEWA CompliantUL / ANSI / NEMA / 60Hz USA Compliant
Request selection sheet & curve →

Direct B2B Supply & Certification Available in Your Region:

Applications & Engineering Use

B2B and municipal application scope.

  • 3-phase motor starting
  • Pumps
  • Blowers & compressors
  • Conveyors
  • Industrial loads

Key Quality Features

Designed for export-grade longevity.

  • DOL (≤ 5 HP) / Star-Delta (5–60 HP) / Auto-Transformer (≥ 60 HP)
  • Soft-starter option
  • Thermal overload with single-phasing protection
  • Conforms to IEC 61439 / IS 8623
B2B Procurement FAQs

Technical Specifications
Motor rating0.75 kW (1 HP) to 150 kW (200 HP)
Supply380–415 V (3Φ) 4-wire
Short-circuit withstand10 / 25 / 50 kA
EnclosureIP54 / IP55 / IP65
Engineering & Export Support

Duty-point specific selection curves, CAD dimensional drawings, and export technical schedules shared immediately with RFQ submissions.

Technical Overview & Standards

motor starter panel manufacturer — Global B2B Technical Specifications

Product overview

Motor Starter Panel (DOL / Star-Delta / Auto-Transformer) from SUPERTECH WATER SOLUTION is engineered for B2B procurement where reliability, documentation, and lifecycle cost matter. This Starter Panels (DOL / Star-Delta / MCC) portfolio is built for government departments, EPC contractors, infrastructure companies, industrial plants, agricultural duty cycles, water treatment operators, and export buyers. We support projects across United States, Houston, Los Angeles, Miami, New York, India, Ahmedabad, Gujarat, UAE, Dubai, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Africa.

Applications and industries served

Industrial procurement teams typically select Motor Starter Panel (DOL / Star-Delta / Auto-Transformer) based on duty point, source conditions, water quality, voltage, and installation constraints. Common applications include: 3-phase motor starting; Pumps; Blowers & compressors; Conveyors; Industrial loads. Industries served include infrastructure, municipal utilities, agriculture and irrigation, industrial manufacturing plants, builders and developers, and EPC project environments. For export projects, selection is aligned to spares availability, site serviceability, and documentation quality.

Key engineering features

SUPERTECH WATER SOLUTION focuses on consistent engineering fundamentals that matter in real installations: stable hydraulics, durable materials, robust electrical protection, and service-friendly assembly. Key highlights include: DOL (≤ 5 HP) / Star-Delta (5–60 HP) / Auto-Transformer (≥ 60 HP); Soft-starter option; Thermal overload with single-phasing protection; Conforms to IEC 61439 / IS 8623. Our export-focused approach emphasises predictable performance and clearer documentation for faster tender evaluation and RFQ comparison.

Technical specifications for procurement

Technical selection is most accurate when duty point is defined — head, discharge, flow rate — along with installation parameters such as borewell diameter, installation depth, voltage, and phase. This product family supports configuration-based selection. Typical specification references include power rating, head range, capacity, pipe sizing, voltage band, material grades, and protection class. All published performance data is tested at 2880 RPM under nominal supply. Site-specific duty-point curves are supplied with every RFQ submission. If you need a customised datasheet for tender submission, request it via our RFQ page with your duty point and destination country.

How to select the right configuration

Correct selection begins with the system curve — total dynamic head (TDH) as a function of flow rate — not just the rated head at the catalogue duty point. TDH includes static head (vertical lift from water level to discharge point), friction losses in column pipe and surface pipework, and any residual pressure required at the delivery point. For borewell installations, the draw-down level under pumping conditions should be used, not the static water level. Motor type — Oil Filled (OF) versus Water Filled (WF) — is selected based on single-phase versus three-phase availability, required HP, and motor OD compatibility with the borewell casing diameter. Under-sizing causes overheating and premature motor failure; over-sizing wastes energy and increases capital cost. Use our RFQ form to share your duty point and receive a matched configuration with a performance curve.

Material of construction and corrosion resistance

Material selection is critical for long service life in varied water qualities — from clean municipal supply to sandy, brackish, or chemically aggressive borewell water. Key wetted parts are selected for resistance to abrasion, corrosion, and chemical attack. For applications in coastal areas, desert environments (UAE, Oman, Saudi Arabia), or high-chloride groundwater, the correct material grade significantly extends service intervals. When in doubt, specify the water quality — TDS, pH, sand content, and temperature — in your RFQ so the engineering team can confirm compatibility.

Voltage, frequency, and electrical compatibility

SUPERTECH WATER SOLUTION manufactures pump sets for both 50 Hz and 60 Hz supply to serve India and the GCC/international markets. For export to UAE, Saudi Arabia, Qatar, Oman, Kuwait, and Bahrain, 60 Hz variants are available. Confirm supply frequency, voltage band, and phase (single or three phase) at the time of RFQ. Wide voltage band motors are designed to start and operate under the supply fluctuations common in agricultural and rural installations. Refer to the datasheet for the operating voltage range of the specific model selected. For variable frequency drive (VFD) applications, confirm VFD compatibility during selection — not all motor configurations are intended for inverter duty without additional specification.

Installation and commissioning guidance

Correct installation is as important as correct selection. A well-selected pump set under-performs when installed incorrectly. Key installation requirements: the pump must be fully submerged to the minimum submergence depth specified in the datasheet; the motor cable must be correctly rated for submersible duty and the run length; and a motor protection device (overload relay, dry-run protector) must be fitted. The non-return valve (NRV) built into the pump prevents back-siphoning and reduces thrust load at switch-off — the surface NRV, if fitted, should be positioned correctly to avoid excessive back-pressure. Column pipe sizing directly affects friction loss and therefore effective head at the duty point. Under-sized column pipe is a common cause of underperformance.

Export documentation and compliance

For GCC and Africa markets, procurement teams require consistent, professional documentation aligned to EPC and government procurement standards. We support RFQ workflows with technical schedules, brochure packs, application notes, material test certificates (MTR), and pre-shipment inspection (SGS/BV) documentation. Compliance references include IS:8034-2002 (Water Filled motor pumpsets), ISO 9001:2015 quality management, SASO/SABER (Saudi Arabia), DEWA (Dubai/UAE), UL (North America), GOST (Russia/CIS), and BSTI (Bangladesh). Our team can assist with product comparison, recommended configuration, export packing specifications, and supply planning aligned to project milestones.

Serviceability, spares, and lifecycle value

Industrial buyers evaluate more than purchase price — they evaluate downtime risk and lifecycle support. SUPERTECH WATER SOLUTION designs product families with maintainability in mind: clear spares mapping, service access where practical, and cross-compatibility across common configurations within the same series. Spares packs covering wear parts (impellers, bowls, wearing rings, mechanical seals, thrust bearings) are available and can be included with the initial export shipment to reduce future downtime exposure at remote sites. When required, we align spares packs for export projects and EPC commissioning timelines.

B2B procurement FAQ

If you are comparing suppliers for motor starter panel manufacturer, focus on documentation clarity, performance transparency, and after-sales readiness. Ask for the exact configuration matching your duty point, request a technical table for comparison, and ensure the supplier can support export packing and lead times. Key questions: Does the supplier publish performance curves at the rated duty point, or only headline head and flow? Are material certificates available? Can the configuration be tested at the factory before shipment? Related searches covered by this page include: star delta starter, auto transformer starter, DOL starter panel, 60Hz motor starter KSA, submersible motor starter Dubai. Our team supports these workflows for India and export markets across United States, Houston, Los Angeles, Miami, New York, India, Ahmedabad, Gujarat.

USA import and 60Hz electrical compatibility

SUPERTECH WATER SOLUTION actively exports Motor Starter Panel (DOL / Star-Delta / Auto-Transformer) to the United States market, with 60Hz variants configured for North American electrical infrastructure. US electrical systems operate at 60Hz with common voltages of 110V (single-phase residential), 220V (single-phase commercial), and 460V (three-phase industrial). Our manufacturing supports all three voltage bands with NEMA frame-compatible motor configurations rated at 3450 RPM. For US procurement teams, all export documentation is prepared for US Customs and Border Protection (CBP) clearance, including HS Code classification (8413.70 for submersible pumps, 8501 for motors), Certificate of Origin (COO), commercial invoice with FOB/CIF terms, and packing list with net/gross weights. UL-ready engineering documentation, ANSI/NEMA specification compliance, and IEEE motor standards are maintained for US regulatory review. Factory test certificates and material test reports (MTR) are included with every shipment. We deliver to major US ports including Houston TX (Port of Houston), Los Angeles CA (Port of Long Beach), Newark NJ (Port New York/New Jersey), and Miami FL (PortMiami) via containerized ocean freight (FCL/LCL) with 21–35 day transit time. Payment terms for US buyers include wire transfer (TT), letter of credit (LC), and USD pricing. For distributor and OEM partnerships in the United States, contact our export sales desk for volume pricing and technical schedules.

RFQ